update_ict_analysis_props#
- Analysis.update_ict_analysis_props(project, ict_analysis_properties)#
Update properties for an ICT analysis.
Available Since: 2024R1
- Parameters:
project (str) – Name of the Sherlock project.
ict_analysis_properties (list) –
ICT analysis properties for a CCA consisting of these properties:
- cca_namestr
Name of the CCA.
- ict_application_timedouble
Specifies the amount of time to complete one ICT event.
- ict_application_time_unitsstr
Application time units. Options are
"ms"
,"sec"
,"min"
,"hr"
,"day"
,"year"
.
- ict_number_of_events: int
Specifies the number of events to apply to the application time when computing the time to failure for a component.
- part_validation_enabled: bool
Whether to enable part validation. The default is
None
.
- require_material_assignment_enabled: bool
Whether to require material assignment. The default is
None
.
- ict_result_count: int
The number of ICT result layers to generate. This parameter is for use with thermal analysis.
- Returns:
Status code of the response. 0 for success.
- Return type:
int
Examples
>>> from ansys.sherlock.core.launcher import launch_sherlock >>> sherlock = launch_sherlock() >>> sherlock.project.import_odb_archive( "ODB++ Tutorial.tgz", True, True, True, True, project="Test", cca_name="Card", ) >>> sherlock.analysis.update_ict_analysis_props( "Test", [{ "cca_name": "Card", "ict_application_time": 2, "ict_application_time_units": "sec", "ict_number_of_events": 10, "part_validation_enabled": False, "require_material_assignment_enabled": False, }, ] )